Steel Stud And Track

STEEL STUD AND TRACK FOR DRYWALL PARTITIONS

TAKE ADVANTAGE OF THE SAVINGS IN TIME AND MONEY OFFERED BY STEEL STUD CONSTRUCTION.

A FEW OF THE MANY BENEFITS ARE:

  • steel studs are manufactured to exact size requirements.
  • steel studs are pre-punched for services
  • steel studs do not warp, eliminating nail popping
  • steel is non-combustible
  • steel studs and track partitions are lightweight and extremely fast to install

METRIC/IMPERIAL CONVERSION TABLE

STUD & TRACK SIZES
IMPERIAL 1 5/8 2 1/2 3 5/8 6
METRIC 41 mm 64 mm 92 mm 152 mm

INTERIOR NON-COMPOSITE LIMITING WALL HEIGHT TABLE

Notes:

  • Studs are 0.0179 in. base steel thickness.
  • Limiting heights are based on continuous support of each flange over the full height of the stud.
  • Heights based on steel properties only,calculated in accordance with CSA-S136-2002.
STUD DESIGNATION SPACING
o.c.(in.)
5 psf 7.5 psf 10 psf
L/120 L/240 L/360 L/120 L/240 L/360 L/120 1L/240 L/360
250S125-18 12 12-6 10-6 9-2 10-2 9-2 8-0 8-10 8-4 7-4
16 10-10 9-6 8-4 8-10 8-4 7-4 7-7 7-7 6-7
24 8-10 8-4 7-4 7-2 7-2 6-4 6-2 6-2 5-10
360S125-18 12 15'-1" 13'-7" 11'-11" 12'-5" 11'-11" 10'-5" 10'-8" 10'-8" 9'-5"
24 13'-1" 12'-5" 10'-10" 10'-8" 10'-8" 9'-5" 9'-4" 9'-4" 8'-7"
24 10'-8" 10'-8" 9'-5" 8'-8" 8'-8" 8'-4" 7'-7" 7'-7" 7'-6"
NOTE: 600S125-18 walls must be constructed with full sheathing, see note 2 below and use corresponding Composite Table.

INTERIOR COMPOSITE LIMITING WALL HEIGHT TABLE

Notes:

  • Studs are 0.0179 in. base steel thickness.
  • Composite wall sheathed both sides full height with 1/2" gypsum wallboard.
  • Sheathing attached with #6 screws minimum at 12" o.c. maximum.
  • Maximum heights are also applicable to walls sheathed with gypsum board greater than 1/2 in. thick and multiple layers of gypsum board.
STUD DESIGNATION SPACING
o.c.(in.)
5 psf 7.5 psf 10 psf
L/120 L/240 L/360 L/120 L/240 L/360 L/120 1L/240 L/360
250S125-18 12 112'-6 10-6 9-2 10-2 9-2 8-0 8-10 8-4 7-4
16 17 18 19 21 12 12 12 12 12
24 17 18 19 21 1 2 2 2 2
360S125-18 12 16-11 15-4 13-4 13-7 13-2 11-6 11-8 11-8 10-5
16 15-1 14-4 12-5 12-1 12-1 10-10 10-5 10-5 9-8
24 13-0 13-0 11-5 10-5 10-5 19-11 8-11 8-11 8-11
2600S125-18 12 21-5 21-5 19-6 17-2 17-2 16-10 14-10 14-10 14-10
16 19-0 19-0 18-2 15-2 15-2 15-2 13-0 13-0 13-0
24 16-2 16-2 16-2 1-11 12-11 12-11 11-0 11-0 11-0